Permit Case Summary

Case Number: Search Help

Case Number:SEP1997-00035 Case Status:Finaled Date Received:2/27/1997
Description: Date Issued:4/8/1997
Applicant:DON YOUNG Expiration Date:4/8/1998 12:00:00 AM
Site Address:906 NESS' CORNER RD Case Finaled:9/17/1998
Parcel No:901024113 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: OSS Inspection-5 Year
Date Completed: 7/1/2003
Disposition: DONE
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 9/17/1998
Disposition:
Description: Renewal Notice Printed (F)
Date Completed: 4/3/1998
Disposition:
Description: PUD Monitoring Contract ltr"L"
Date Completed: 4/3/1998
Disposition:
Description: PUD contract required
Date Completed: 9/16/1998
Disposition:
Description: AsBuilt from engineer req
Date Completed: 1/16/1998
Disposition:
Description: Pressure test required
Date Completed: 12/8/1997
Disposition:
Description: Partial Final/cont Renewal "T"
Date Completed: 12/8/1997
Disposition: T
Description: Issue permit (F)
Date Completed: 4/8/1997
Disposition: ISS
Description: Case Entered
Date Completed: 2/27/1997
Disposition:
Description: Review Case
Date Completed: 3/27/1997
Disposition: PO
Description: Critical Area Review
Date Completed: 3/4/1997
Disposition:
Description: Septic Permit Application (F)
Date Completed: 3/3/1997
Disposition:

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: pud monitoring
Wording AS PER WAC 246-272 ALL ALTERNATIVE SYSTEMS REQUIRE MONITORING. THIS MONITORING IS PROVIDED BY AGREEMENT BETWEEN THE JEFFERSON COUNTY ENVIRONMENTAL HEALTH DIVISION AND THE JEFFERSON COUNTY PUBLIC UTILITY DISTRICT #1. THIS SEWAGE DISPOSAL SYSTEM WILL REQUIRE AN ACTIVE MONITORING CONTRACT WITH THE PUD #1 PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL SYSTEM.

Title: pressure test observation
Wording Health Dept. required to observe pressure test, 48 hour notice to be given.

Title: well setback requirement
Wording 100 ft. setback to all wells to be maintained

Title: other setbacks req.
Wording 10 ft. separation between water lines and all portions of onsite sewage system to be maintained.

Title: low use water fixures
Wording Low use water fixtures required, 1.6 gal. flush toilets and 2.5 gpm shower heads.

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance. Protective barriers are required around drainfield.

Title: dose counter
Wording Dose counters are required in the control panel for all drainfield components.

Title: divert drainage
Wording Divert all sources of drainage away from septic tank and drainfield area.

Title: transport line double cased
Wording Any portion of transport line under a driven way is to be double cased or equivalent.

Title: water tight tank
Wording Asphaultic emulsion or equivalent required on septic tank and/or pump chamber.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: SAND LINED TRENCH/BED
Wording TRENCH TO BE EXCAVATED AS PER PLAN AND THEN BACKFILLED WITH ASTM 33 TYPE SAND TO 24" AND UP SIDE WALLS AS PER DESIGN.

Title: critical area compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Critical Areas Ordinance for other development on the site.

Title: domestic strength waste
Wording This onsite sewage system is designed for domestic strength waste water only. Disposal of any other waste streams is considered a violation of this permit.

Title: design flow/water usage monitorin
Wording Exceeding the permitted design flow of 480 gal/day shall constitute a violation of this permit. Water usage monitoring may be required by the Health Dept to verify usage. These monitoring results shall be submitted to the Jefferson County Health Dept when requested.

Title: risers
Wording Risers are required to grade with secured lids over the inlet and outlet of the septic tank. Minimum 24" riser over inlet.