Case Number:SEP1997-00025 Case Status:Violation Date Received:2/20/1997
Description:Prior to any building permit approvals on this parcel, water use records must be evaluated to ensure over use is not occurring. See file for information from water use review from 9/07. SP EES ON 10/10/2005 Date Issued:3/10/1997
Applicant:HAROLD MOE Expiration Date:3/10/1998 12:00:00 AM
Site Address:11255 RHODY DR Case Finaled:9/4/1997
Parcel No:994200021 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: VIOLATION/COMPLIANCE (F) "V"
Date Completed: 9/12/2007
Disposition: DONE
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 9/4/1997
Disposition:
Description: Issue permit (F)
Date Completed: 3/10/1997
Disposition: ISS
Description: Case Entered
Date Completed: 2/20/1997
Disposition:
Description: Review Case
Date Completed: 3/10/1997
Disposition: ISS
Description: Critical Area Review
Date Completed: 2/24/1997
Disposition:
Description: Inspection
Date Completed: 9/4/1997
Disposition:
Description: Septic Permit Application (F)
Date Completed: 2/20/1997
Disposition:

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: well setback requirement
Wording 100 ft. setback to all wells to be maintained

Title: other setbacks req.
Wording 5 ft. setback from road right of way to be maintained.

Title: other setbacks req.
Wording 50 ft. setback from existing well to septic tank to be maintained unless the well is used as a public water supply. If the well is used as a public water supply a 100' setback to the tanks is required.

Title: other setbacks req.
Wording There shall be no cross connection between the existing well and the public water system. Prior to issuance of building permit or other development of the site the owner shall provide written documentation that the City has reviewed the plan for any use of this well.

Title: trench depth
Wording MAXIMUM TRENCH DEPTH 12 INCHES

Title: reserve area, alternative
Wording When/if designated reserve area is utilized an alternative system may be required.

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance. Protective barriers are required around drainfield.

Title: divert drainage
Wording Divert all sources of drainage away from septic tank and drainfield area.

Title: water tight tank
Wording Asphaultic emulsion or equivalent required on septic tank and/or pump chamber.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: critical area compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Critical Areas Ordinance for other development on the site.

Title: domestic strength waste
Wording This onsite sewage system is designed for domestic strength waste water only. Disposal of any other waste streams is considered a violation of this permit.

Title: design flow/water usage monitorin
Wording Exceeding the permitted design flow of 240 gal/day shall constitute a violation of this permit. Water usage monitoring may be required to verify compliance with the permit. Said monitoring shall be submitted to Jefferson County Health Dept.