Permit Case Summary

Case Number: Search Help

Case Number:SEP1996-00354 Case Status:Finaled Date Received:11/22/1996
Description:holding tank serving the boat pump out at the marina. Date Issued:12/27/1996
Applicant: PORT HADLOCK/ K S C LLC Expiration Date:12/27/1997 12:00:00 AM
Site Address:310 HADLOCK BAY RD Case Finaled:10/6/1997
Parcel No:901014007 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 10/6/1997
Disposition:
Description: Issue permit (F)
Date Completed: 12/27/1996
Disposition: ISS
Description: Case Entered
Date Completed: 11/22/1996
Disposition:
Description: Review Case
Date Completed: 12/27/1996
Disposition: ISS
Description: Critical Area Review
Date Completed: 12/2/1996
Disposition:
Description: Inspection
Date Completed: 9/25/1997
Disposition: OKAY
Description: Septic Permit Application (F)
Date Completed: 11/25/1996
Disposition:

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance. Protective barriers are required around tank.

Title: transport line double cased
Wording Any portion of transport line under a driven way is to be double cased or equivalent. Transport line to be double cased where within 100' of surface water/shoreline.

Title: water tight tank
Wording Asphaultic emulsion or equivalent required on septic tank and/or pump chamber.

Title: CUSTOM CONDITION
Wording Risers to grade with secured lids shall be located over all compartments. All access ports intended to be used a pump-out sites shall be fitted with an impervious pad that slopes towards the access so that any spillage or washdown drains back into the holding tank.

Title: CUSTOM CONDITION
Wording All pumping and related service must be performed by a Jefferson County licensed septic system pumper.

Title: CUSTOM CONDITION
Wording A high water float with an audio visual alarm shall be provided. The alarm shall be located within view of the holding tank in a watertight enclosure and approved by the State Electrical Inspector.

Title: CUSTOM CONDITION
Wording Prior to final approval, the applicant shall submit to the Health Dept. written documentation of a service contract with a licensed pumper.

Title: CUSTOM CONDITION
Wording Permit holder shall maintain and keep operational records which include pumping intervals, sewage volume, disposal site, service and repair records. These records shall be made available to an authorized representative of the Jefferson County Health Dept. upon request.

Title: CUSTOM CONDITION
Wording Pump test to be completed from marina pumpout station prior to final approval.