Permit Case Summary

Case Number: Search Help

Case Number:SEP1996-00291 Case Status:Finaled Date Received:9/16/1996
Description: Date Issued:10/24/1996
Applicant:DONALD SPIGARELLI Expiration Date:10/24/1997 12:00:00 AM
Site Address: RHODY DR Case Finaled:8/21/1997
Parcel No:942902202 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 8/21/1997
Disposition:
Description: Issue permit (F)
Date Completed: 10/24/1996
Disposition: ISS
Description: Case Entered
Date Completed: 9/16/1996
Disposition:
Description: Review Case
Date Completed: 10/17/1996
Disposition: PD
Description: Critical Area Review Complete
Date Completed: 9/27/1996
Disposition:
Description: Inspection
Date Completed: 8/21/1997
Disposition:
Description: Septic Permit Application (F)
Date Completed: 9/16/1996
Disposition:

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: well setback requirement
Wording 100 ft. setback to all wells to be maintained

Title: other setbacks req.
Wording 100 ft. setback from all surface waters to be maintained.

Title: trench depth
Wording MAXIMUM TRENCH DEPTH 36 INCHES

Title: low use water fixures
Wording Low use water fixtures required, 1.6 gal. flush toilets and 2.5 gpm shower heads.

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance. Protective barriers are required around drainfield.

Title: installed on natural contours
Wording Drainlines are to be installed along the natural contours.

Title: divert drainage
Wording Divert all sources of drainage away from septic tank and drainfield area.

Title: transport line double cased
Wording Any portion of transport line under a driven way is to be double cased or equivalent.

Title: water tight tank
Wording Asphaultic emulsion or equivalent required on septic tank and/or pump chamber.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: critical area compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Critical Areas Ordinance for other development on the site.

Title: domestic strength waste
Wording This onsite sewage system is designed for domestic strength waste water only. Disposal of any other waste streams is considered a violation of this permit.