Permit Case Summary

Case Number: Search Help

Case Number:SEP1996-00154 Case Status:Finaled Date Received:5/9/1996
Description:Filed with SEP21-219 Date Issued:7/3/1996
Applicant:SCOTT BROWNING Expiration Date:7/3/1997 12:00:00 AM
Site Address:846 NESS' CORNER RD Case Finaled:4/25/1997
Parcel No:901024111 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: Document Recorded
Date Completed: 7/2/2013
Disposition:
Description: OSS Inspection-2 Year
Date Completed: 6/4/2002
Disposition: DONE
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 4/25/1997
Disposition:
Description: Issue permit (F)
Date Completed: 7/3/1996
Disposition: ISS
Description: Case Entered
Date Completed: 5/9/1996
Disposition:
Description: Review Case
Date Completed: 5/23/1996
Disposition: PO
Description: Critical Area Review Complete
Date Completed: 6/3/1996
Disposition: F
Description: Septic Permit Application (F)
Date Completed: 5/10/1996
Disposition:

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: pud monitoring
Wording AS PER WAC 246-272 ALL ALTERNATIVE SYSTEMS REQUIRE MONITORING. THIS MONITORING IS PROVIDED BY AGREEMENT BETWEEN THE JEFFERSON COUNTY ENVIRONMENTAL HEALTH DIVISION AND THE JEFFERSON COUNTY PUBLIC UTILITY DISTRICT #1. THIS SEWAGE DISPOSAL SYSTEM WILL REQUIRE AN ACTIVE MONITORING CONTRACT WITH THE PUD #1 PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL SYSTEM.

Title: pressure test observation
Wording Health Dept. required to observe pressure test, 48 hour notice to be given.

Title: setback requirement
Wording 100 ft. setback to all wells to be maintained

Title: low use water fixures
Wording Low use water fixtures required, 1.6 gal. flush toilets and 2.5 gpm shower heads.

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance. Protective barriers are required around drainfield.

Title: dose counter
Wording Dose counters are required in the control panel for all drainfield components.

Title: transport line double cased
Wording Any portion of transport line under a driven way is to be double cased or equivalent.

Title: community drainfield
Wording If this community drainfield, servs more than one business or residence owned by different parties, it will require a management and operations agreement with an entity approved by the Jefferson County Health Department as per Jefferson County Policy.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of a building permit on this site.

Title: SAND LINED TRENCH/BED
Wording TRENCH/BED TO BE EXCAVATED TO 48" DEPTH AND THEN BACKFILLED WITH ASTM 33 TYPE SAND TO 24" AND UP SIDE WALLS AS PER DESIGN.

Title: critical area compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Critical Areas Ordinance for other development on the site.

Title: CUSTOM CONDITION
Wording WAC 246-272 REQUIRES ANNUAL MONITORING OF THE ONSITE SEWAGE SYSTEMS SERVING FOOD SERVICE ESTABLISHMENTS

Title: CUSTOM CONDITION
Wording This system is designed to treat and dispose of domestic strength waste water only. Biological Oxygen Demand (BOD), grease and oils and dissolved oxygen testing will be completed on a quarterly basis for the first year of operation and on an annual basis thereafter. If the waste strength exceeds 300 mg/l a pretreatment device will be added to the system to manage the waste strength.