Permit Case Summary

Case Number: Search Help

Case Number:SEP1996-00087 Case Status:Finaled Date Received:3/25/1996
Description:lot 3 Date Issued:8/13/1999
Applicant:DICK BRODERS Expiration Date:8/13/2000 12:00:00 AM
Site Address:116 PORT HADLOCK HEIGHTS RD Case Finaled:10/22/1999
Parcel No:989506103 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 10/22/1999
Disposition:
Description: Issue permit (F)
Date Completed: 8/13/1999
Disposition: ISS
Description: Case Entered
Date Completed: 3/25/1996
Disposition:
Description: Review Case
Date Completed: 8/13/1999
Disposition: ISS
Description: Critical Area Review Complete
Date Completed: 4/3/1996
Disposition:
Description: Septic Permit Application (F)
Date Completed: 3/26/1996
Disposition:

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: trench depth
Wording MAXIMUM TRENCH DEPTH 28 INCHES

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance. Protective barriers are required around drainfield.

Title: installed on natural contours
Wording Drainlines are to be installed along the natural contours.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and drainfield area.

Title: transport line double cased
Wording Any portion of transport line under a driven way is to be double cased or equivalent.

Title: water tight tank
Wording Asphaultic emulsion or equivalent required on septic tank and/or pump chamber.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: critical area compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Critical Areas Ordinance for other development on the site.

Title: risers
Wording Risers are highly recommended to grade with secured lids over the inlet and outlet of the septic tank. Minimum 24" riser over inlet.