Permit Case Summary

Case Number: Search Help

Case Number:SEP1996-00085 Case Status:Finaled Date Received:3/25/1996
Description:lot 4 of Port Hadlock Heights with individual DF EES 8/6/07 Date Issued:3/22/2000
Applicant:DICK BRODERS Expiration Date:3/22/2003 12:00:00 AM
Site Address:113 PORT HADLOCK HEIGHTS RD Case Finaled:1/8/2001
Parcel No:989506104 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 1/8/2001
Disposition: DONE
Description: Issue permit (F)
Date Completed: 3/22/2000
Disposition: DONE
Description: Issue permit (F)
Date Completed: 3/22/2000
Disposition: DONE
Description: Case Entered
Date Completed: 3/25/1996
Disposition:
Description: Review Case
Date Completed: 3/22/2000
Disposition: DONE
Description: Critical Area Review Complete
Date Completed: 4/3/1996
Disposition:
Description: Septic Permit Application (F)
Date Completed: 3/26/1996
Disposition:

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: trench depth
Wording MAXIMUM TRENCH DEPTH 12 INCHES

Title: reserve area, alternative
Wording When/if designated reserve area is utilized an alternative system providing an additional level of treatment may be required.

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance.

Title: installed on natural contours
Wording Drainlines are to be installed along the natural contours.

Title: staking of drainfield
Wording Contact designer prior to installation for staking of drainfield area.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and drainfield area.

Title: transport line double cased
Wording Any portion of transport line under a driven way is to be double cased or equivalent.

Title: water tight tank
Wording Asphaultic emulsion or equivalent required on septic tank and/or pump chamber.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: critical area compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Critical Areas Ordinance for other development on the site.

Title: risers
Wording Risers are required to grade with secured lids over the inlet and outlet of the septic tank. Minimum 24" riser over inlet.

Title: PROTECTIVE BARRIERS-HOLD
Wording Barriers are to be placed around the primary and reserve drainfield areas to protect from parking, driving and other land disturbing activities. Ok per La 1/29/01