Permit Case Summary

Case Number: Search Help

Case Number:SEP1996-00081 Case Status:Canceled Date Received:3/25/1996
Description:filed to SEP06-139, now connecting to Community System "C", SEP95-290. lot 25 Date Issued:9/9/2002
Applicant:DICK BRODERS Expiration Date:9/9/2005 12:00:00 AM
Site Address:412 PORT HADLOCK HEIGHTS RD Case Finaled:
Parcel No:989500001 Other Cases Parcel Data Map It More Details

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: Cancel/withdraw application
Date Completed: 10/11/2005
Disposition: DONE
Description: Issue permit (F)
Date Completed: 9/9/2002
Disposition: DONE
Description: Pending letter; add inf (F)
Date Completed: 9/9/2002
Disposition: DONE
Description: change final date
Date Completed: 1/1/1900
Disposition: DONE
Description: Return Case Status to Pending
Date Completed: 3/5/2001
Disposition: DONE
Description: Case Entered
Date Completed: 3/25/1996
Disposition:
Description: Review Case
Date Completed: 9/9/2002
Disposition: DONE
Description: Critical Area Review Complete
Date Completed: 4/3/1996
Disposition:
Description: Septic Permit Application (F)
Date Completed: 3/26/1996
Disposition:

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: trench depth
Wording MAXIMUM TRENCH DEPTH 24 INCHES

Title: installed on natural contours
Wording Drainlines are to be installed along the natural contours.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and drainfield area.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: UDC compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Unified Development Code for other/future development on the site.

Title: risers
Wording Risers are required to grade with secured lids over the inlet and outlet of the septic tank. Minimum 24" riser over inlet.

Title: MONITORING SCHEDULE
Wording As per Jefferson County Code 8.15 all onsite sewage systems require monitoring. Monitoring shall be provided by an approved entity. THIS SYSTEM IS REQUIRED TO BE INSPECTED EVERY 3 YEARS

Title: conventional-asbuilt required
Wording An asbuilt drawing and certification of completion by the installer is required prior to final approval.

Title: protective barriers
Wording Permanent barriers are required along/around primary and reserve drainfield areas to protect from parking, driving, and other land disturbing activities prior to final.

Title: riser on d-box
Wording Distribution boxes shall be fitted with a riser to grade, constructed of durable materials and a secured lid, adequately sized to allow visible inspection of the liquid level in the box.

Title: Water line setback
Wording 10' separation required between a Water line and all portions of the primary and reserve onsite sewage system; effluent transport line, tanks, treatment and disposal components.

Title: Stormwater BMPs
Wording The project shall adhere to the Best Management Practices (BMPs) to control stormwater, erosion and sediment during construction. BMPs shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems.