Permit Case Summary

Case Number: Search Help

Case Number:SEP1996-00012 Case Status:Finaled Date Received:1/19/1996
Description: Date Issued:2/26/1996
Applicant:JERRY HOEPPNER Expiration Date:2/26/1997 12:00:00 AM
Site Address:1561 IRONDALE RD Case Finaled:7/2/1997
Parcel No:994800213 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: OSS Inspection-Custom Schedule
Date Completed: 4/11/2007
Disposition: DONE
Description: OSS Inspection-2 Year
Date Completed: 9/5/2002
Disposition: DONE
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 7/2/1997
Disposition:
Description: Partial Final/cont Renewal "T"
Date Completed: 4/1/1997
Disposition: T
Description: Renewal Notice Printed (F)
Date Completed: 1/16/1997
Disposition:
Description: Issue permit (F)
Date Completed: 2/26/1996
Disposition: ISS
Description: Case Entered
Date Completed: 1/19/1996
Disposition:
Description: Review Case
Date Completed: 2/26/1996
Disposition: ISS
Description: Critical Area Review Complete
Date Completed: 2/26/1996
Disposition:
Description: Septic Permit Application (F)
Date Completed: 1/19/1996
Disposition:

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: pud monitoring
Wording AS PER WAC 246-272 ALL ALTERNATIVE SYSTEMS REQUIRE MONITORING. THIS MONITORING IS PROVIDED BY AGREEMENT BETWEEN THE JEFFERSON COUNTY ENVIRONMENTAL HEALTH DIVISION AND THE JEFFERSON COUNTY PUBLIC UTILITY DISTRICT #1. THIS SEWAGE DISPOSAL SYSTEM WILL REQUIRE AN ACTIVE MONITORING CONTRACT WITH THE PUD #1 PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL SYSTEM.

Title: pressure test observation
Wording Health Dept. required to observe pressure test, 48 hour notice to be given.

Title: setback requirement
Wording 6' ft. setback to residence to be maintained.

Title: low use water fixures
Wording Low use water fixtures required, 1.6 gal. flush toilets and 2.5 gpm shower heads.

Title: staking of drainfield
Wording Contact designer prior to installation for staking of drainfield area.

Title: dose counter
Wording Dose counters are required in the control panel for all drainfield components.

Title: transport line double cased
Wording Any portion of transport line under a driven way is to be double cased or equivalent.

Title: water tight tank
Wording Asphaultic emulsion or equivalent required on septic tank and/or pump chamber.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of a building permit on this site.

Title: critical area compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Critical Areas Ordinance for other development on the site.

Title: CUSTOM CONDITION
Wording This system is a repair to an existing system and does not comply with current code requirements for setback to a bank or a residence. The setback from the bank has been reduced to approximately 12'. The WAC 246-272 requires a minimum of 25'. The setback to the house has been reduced to 6', the WAC requires 10'. No alterations or expansions beyond the existing footprint of the residence shall be permitted unless a reserve drainfield site can be identified.