Description:
|
| | |
Close Case/Retrn status to "F"
|
|
Date Completed:
|
| | |
2/20/2019
|
|
Disposition:
|
| | |
DONE
|
|
|
Description:
|
| | |
REDESIGN SUBMITTED (Fm) "P"
|
|
Date Completed:
|
| | |
2/20/2019
|
|
Disposition:
|
| | |
DONE
|
|
|
Description:
|
| | |
SEPTIC PERMIT FINALED "F"
|
|
Date Completed:
|
| | |
1/4/2002
|
|
Disposition:
|
| | |
DONE
|
|
|
Description:
|
| | |
PUD contract required
|
|
Date Completed:
|
| | |
3/16/1998
|
|
Disposition:
|
| | |
|
|
|
Description:
|
| | |
AsBuilt from engineer req
|
|
Date Completed:
|
| | |
2/11/1998
|
|
Disposition:
|
| | |
DONE
|
|
|
Description:
|
| | |
Pressure test required
|
|
Date Completed:
|
| | |
9/18/1997
|
|
Disposition:
|
| | |
|
|
|
Description:
|
| | |
Partial Final/cont Renewal "T"
|
|
Date Completed:
|
| | |
9/18/1997
|
|
Disposition:
|
| | |
T
|
|
|
Description:
|
| | |
Issue permit (F)
|
|
Date Completed:
|
| | |
4/6/1997
|
|
Disposition:
|
| | |
ISS
|
|
|
Description:
|
| | |
Case Entered
|
|
Date Completed:
|
| | |
9/19/1995
|
|
Disposition:
|
| | |
|
|
|
Description:
|
| | |
Review Case
|
|
Date Completed:
|
| | |
4/6/1997
|
|
Disposition:
|
| | |
ISS
|
|
|
Description:
|
| | |
Critical Area Review Complete
|
|
Date Completed:
|
| | |
4/6/1997
|
|
Disposition:
|
| | |
|
|
|
Description:
|
| | |
Septic Permit Application (F)
|
|
Date Completed:
|
| | |
9/20/1995
|
|
Disposition:
|
| | |
|
|
|
Title:
|
| | |
pud monitoring
|
|
Wording
|
| | |
AS PER WAC 246-272 ALL ALTERNATIVE SYSTEMS REQUIRE MONITORING. THIS MONITORING IS PROVIDED BY AGREEMENT BETWEEN THE JEFFERSON COUNTY ENVIRONMENTAL HEALTH DIVISION AND THE JEFFERSON COUNTY PUBLIC UTILITY DISTRICT #1. THIS SEWAGE DISPOSAL SYSTEM WILL REQUIRE AN ACTIVE MONITORING CONTRACT WITH THE PUD #1 PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL SYSTEM.
|
|
|
Title:
|
| | |
pressure test observation
|
|
Wording
|
| | |
Health Dept. required to observe pressure test, 48 hour notice to be given.
|
|
|
Title:
|
| | |
well setback requirement
|
|
Wording
|
| | |
100 ft. setback to all wells to be maintained
|
|
|
Title:
|
| | |
other setbacks req.
|
|
Wording
|
| | |
30 ft. setback from downgradient roadside ditches to drainfield to be maintained.
|
|
|
Title:
|
| | |
protection from vehicular traffic
|
|
Wording
|
| | |
All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance. Protective barriers are required around drainfield.
|
|
|
Title:
|
| | |
installed on natural contours
|
|
Wording
|
| | |
Drainlines are to be installed along the natural contours.
|
|
|
Title:
|
| | |
staking of drainfield
|
|
Wording
|
| | |
Contact designer prior to installation for staking of drainfield area.
|
|
|
Title:
|
| | |
dose counter
|
|
Wording
|
| | |
Dose counters are required in the control panel for all drainfield components.
|
|
|
Title:
|
| | |
transport line double cased
|
|
Wording
|
| | |
Any portion of transport line under a driven way is to be double cased or equivalent.
|
|
|
Title:
|
| | |
community drainfield
|
|
Wording
|
| | |
This community drainfield, serving more than one residence, will require a management and operations agreement with an entity approved by the Jefferson County Health Department as per Jefferson County Policy when/if the residences are separately owned or the property is subdivided.
|
|
|
Title:
|
| | |
no building permit guarantee
|
|
Wording
|
| | |
Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.
|
|
|
Title:
|
| | |
SAND LINED TRENCH/BED
|
|
Wording
|
| | |
TRENCH TO BE EXCAVATED AND THEN BACKFILLED WITH ASTM 33 TYPE SAND TO 24" AS PER DESIGN.
|
|
|
Title:
|
| | |
critical area compliance
|
|
Wording
|
| | |
Approval of this sewage disposal permit does not preclude the permit holder from complying with the Critical Areas Ordinance for other development on the site.
|
|
|
Title:
|
| | |
domestic strength waste
|
|
Wording
|
| | |
This onsite sewage system is designed for domestic strength waste water only. Disposal of any other waste streams is considered a violation of this permit.
|
|
|
Title:
|
| | |
CUSTOM CONDITION
|
|
Wording
|
| | |
This community drainfield requires a management agreement with a third party quarantor with adequate funds set aside in an account to repair the system. The third party quarantor shall be the PUD #1. They will take over management and operation of the system if so directed by the Jefferson County Environmental Health Div.
|
|
|
Title:
|
| | |
CUSTOM CONDITION
|
|
Wording
|
| | |
A permit from Jeff. Co. shall be obtained to install a septic tank to serve the residences. As per the plans some residences shall share a tank. If the lots are ever separately owned then individual tanks will be installed on each residence. Each tank shall have risers to grade over the inlet and outlet of the septic tank. An outlet baffle filter is required on the outlet of the tank.
|
|