Permit Case Summary

Case Number: Search Help

Case Number:SEP1993-00276 Case Status:Canceled Date Received:8/3/1993
Description:now filed with SEP09-142. Date Issued:10/5/1994
Applicant:DONALD SHORT Expiration Date:10/5/1997 12:00:00 AM
Site Address:92 N WATER ST Case Finaled:
Parcel No:901012006 Other Cases Parcel Data Map It More Details

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: Cancel/withdraw application
Date Completed: 10/6/1997
Disposition:
Description: Renew Permit
Date Completed: 10/8/1996
Disposition:
Description: Renewal Notice Printed (F)
Date Completed: 10/2/1996
Disposition:
Description: Renew Permit
Date Completed: 11/15/1995
Disposition:
Description: Renewal Notice Printed (F)
Date Completed: 9/22/1995
Disposition:
Description: Issue permit (F)
Date Completed: 10/5/1994
Disposition:
Description: Case Entered
Date Completed: 7/8/1993
Disposition:
Description: Review Case
Date Completed: 8/2/1993
Disposition: PO
Description: REDESIGN SUBMITTED
Date Completed: 8/3/1993
Disposition:
Description: Septic Permit Application (F)
Date Completed: 8/3/1993
Disposition:

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: pud monitoring
Wording AS PER WAC 246-272 ALL ALTERNATIVE SYSTEMS REQUIRE MONITORING. THIS MONITORING IS PROVIDED BY AGREEMENT BETWEEN THE JEFFERSON COUNTY ENVIRONMENTAL HEALTH DIVISION AND THE JEFFERSON COUNTY PUBLIC UTILITY DISTRICT #1. THIS SEWAGE DISPOSAL SYSTEM WILL REQUIRE AN ACTIVE MONITORING CONTRACT WITH THE PUD #1 PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL SYSTEM.

Title: pressure test observation
Wording Health Dept. required to observe pressure test, 48 hour notice to be given.

Title: setback requirement
Wording 100 ft. setback to bulkhead/surface water to be maintained

Title: well abandonment
Wording Well to be abandoned as per WAC 173-160-455 and DOE guidelines by licensed well driller. Verification to be provided to Health Department.

Title: trench depth
Wording MAXIMUM TRENCH DEPTH 18 INCHES

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance. Protective barriers are required around drainfield.

Title: dose counter
Wording Dose counters are required in the control panel for all drainfield components.

Title: transport line double cased
Wording Any portion of transport line under a driven way is to be double cased or equivalent.

Title: water tight tank
Wording Asphaultic emulsion or equivalent required on septic tank and/or pump chamber.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of a building permit on this site.