Description:
|
| | |
File Archived
|
|
Date Completed:
|
| | |
8/27/2003
|
|
Disposition:
|
| | |
DONE
|
|
|
Description:
|
| | |
Close case
|
|
Date Completed:
|
| | |
11/20/2002
|
|
Disposition:
|
| | |
DONE
|
|
|
Description:
|
| | |
TYPE A Appeal Instrctns (F)
|
|
Date Completed:
|
| | |
11/20/2000
|
|
Disposition:
|
| | |
DONE
|
|
|
Description:
|
| | |
Issue SDP Permit
|
|
Date Completed:
|
| | |
11/20/2000
|
|
Disposition:
|
| | |
DONE
|
|
|
Description:
|
| | |
DRD Info Request
|
|
Date Completed:
|
| | |
11/8/2000
|
|
Disposition:
|
| | |
DONE
|
|
|
Description:
|
| | |
App Substantially Complete (F)
|
|
Date Completed:
|
| | |
9/21/2000
|
|
Disposition:
|
| | |
DONE
|
|
|
Description:
|
| | |
(F) SDP Application Notice +30
|
|
Date Completed:
|
| | |
11/17/2000
|
|
Disposition:
|
| | |
DONE
|
|
|
Description:
|
| | |
Pub Date in Leader-Ntc of Appl
|
|
Date Completed:
|
| | |
|
|
Disposition:
|
| | |
|
|
|
Description:
|
| | |
Case Entered
|
|
Date Completed:
|
| | |
9/19/2000
|
|
Disposition:
|
| | |
|
|
|
Description:
|
| | |
Shoreline Planner Review
|
|
Date Completed:
|
| | |
|
|
Disposition:
|
| | |
|
|
|
Title:
|
| | |
Buoy marked
|
|
Wording
|
| | |
The buoy shall be permanently marked with the proponent's name, address, and telephone number and the permit number.
|
|
|
Title:
|
| | |
Buoy placement
|
|
Wording
|
| | |
The buoy shall be placed a minimum of 100 feet from existing permitted or exempted adjacent mooring buoys, docks, and piers. The buoy shall be located at least 100 feet seaward of the minus 6 foot mean lower low water tidal elevation.
|
|
|
Title:
|
| | |
Vessel maintenance activities
|
|
Wording
|
| | |
Vessel maintenance activities which may cause water pollution, including hull chipping and painting, shall be performed at designated facilities.
|
|
|
Title:
|
| | |
Overnight use of buoy
|
|
Wording
|
| | |
Overnight use by vessels with holding tanks shall be limited to three (3) consecutive days before the vessel must have its holding tanks pumped at an approved facility. Overnight use by vessels without holding tanks shall not be permitted. For the purposes of the permit, occupancy of a moored vessel for a period exceeding seven (7) days would constitute residential use and shall be prohibited.
|
|
|
Title:
|
| | |
Buoy discernible from a distance
|
|
Wording
|
| | |
The buoy shall be discernible from a minimum distance of 100 yards under normal daylight conditions.
|
|
|
Title:
|
| | |
Discharge oil: state & fed regs
|
|
Wording
|
| | |
The proponents shall comply with all relevant state and federal regulations pertaining to the discharge of oil.
|
|
|
Title:
|
| | |
HPA ISSUED
|
|
Wording
|
| | |
Hydraulic Project Approval (HPA) was issued by the Washington Department of Fish and Wildlife on October 31, 2000 under Log Number 00-E7815-01. The HPA expires on January 2, 2002.
|
|
|
Title:
|
| | |
SEPA EXEMPT
|
|
Wording
|
| | |
Recreational mooring buoys are exempt from review under the State Environmental Policy Act pursuant to WAC 197-11-800(25).
|
|
|
Title:
|
| | |
NOTICE BEFORE WORK
|
|
Wording
|
| | |
The proponent shall notify the Jefferson County Department of Community Development at (360) 379-4450 forty-eight (48) hours prior to commencing construction in order to allow monitoring and ensure conformance with permit conditions.
|
|
|
Title:
|
| | |
SMP APPROVAL ONLY
|
|
Wording
|
| | |
This approval pertains to Jefferson County Shoreline Management Master Program requirements only. The approval of any other agency with jurisdiction or any other required permits shall be obtained prior to undertaking the project.
|
|
|
Title:
|
| | |
2 BOATS
|
|
Wording
|
| | |
No more than two (2) boats shall be secured by a mooring buoy.
|
|
|
Title:
|
| | |
DNR
|
|
Wording
|
| | |
The applicant is required to possess a valid mooring buoy license from the Washington Department of Natural Resources for placement of a mooring buoy on State Owned Aquatic Lands.
|
|
|
Title:
|
| | |
CUSTOM CONDITION
|
|
Wording
|
| | |
DUE TO CONTAMINATION CONCERNS, IT IS IMPERATIVE THAT NO HUMAN WASTE BE DISCHARGED INTO MYSTERY BAY. THE USE OF A PUMP-OUT FACILITY IS MANDATORY.
|
|
|
Title:
|
| | |
Comply with HPA
|
|
Wording
|
| | |
The proposal must comply with all applicable conditions as set forth in the Hydraulic Project Approval.
|
|
|
Title:
|
| | |
ARMY CORPS. LANGUAGE
|
|
Wording
|
| | |
The proponent is responsible for applying to the Corps of Engineers for a Department of the Army (DA) Permit. A DA permit shall be obtained prior to the performance of any activities waterward of the mean high water mark or ordinary high water mark or in wetlands. Please contact Mr. Jack Gossett or Ms. Susan Glenn at (206) 764-6902 or 6904, respectively for more information. Information can also be obtained from the U.S. Army Corps of Engineers, Regulatory Branch, Post Office Box 3755, Seattle, Washington 98124.
|
|