Case Number:RAP2002-00294 Case Status:Finaled Date Received:12/24/2002
Description:Utility Installation - Chimacum Rd / Elkins Rd Date Issued:10/9/2003
Applicant:JAMES PARKER Expiration Date:1/9/2004 12:00:00 AM
Site Address:83 ELKINS RD Case Finaled:2/28/2005
Parcel No:901111009 Other Cases Parcel Data Map It

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: Final Inspection Approval
Date Completed: 2/28/2005
Disposition: DONE
Description: Issue Permit
Date Completed: 10/9/2003
Disposition: DONE
Description: Issue Permit
Date Completed: 12/30/2002
Disposition: DONE
Description: Case Entered
Date Completed: 12/24/2002
Disposition:

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: DEPTH 30"
Wording Minimum cover allowed over utility lines placed accross or parallel to the roadway shall be no less than 30" below the level of the ditch or ground level.

Title: YESCUT
Wording The pavement shall be sawcut and the trench shall be backfilled with (C.D.F.) or a Concrete Density Slurry or gravel and compacted in 12 inch lifts. The final lift shall be 3 inches of Asphalt Concrete Pavement which shall include at least 2 feet on each side of the trench. The joints shall be sealed with a petroleum based oil such as C.S.S. #1 or a similar product.

Title: TRENCHCUT
Wording The utility trench shall be backfilled and mechanically compacted.

Title: WORKER/ROW
Wording Any time that workers are on the county right-of-way warning signs shall be posted that workers are present. All workers shall comply with applicable Labor and Industries Guidelines for clothing including reflective vests. Any time that equipment must enter onto the right-of-way, signing and flaggers shall be used in accordance with applicable MUTCD standards.

Title: NOTINSHOULDER
Wording The applicant shall not place any utilities in the roadway shoulder defined as 2'-4' off edge of pavement.


Case Findings
Below is a list of findings for this permit case. Findings typically record facts that the staff are using as the basis of their permit processing decisions.
Title: P-OPEN CUT
Wording The applicant may open cut Chimacum Rd. at milepost 0.63 left to tap into the existing water line for the extension of an 8" waterline down Elkins Rd. The cut shall be limited to what is necessary to make the tap.

Title: P-UTILITIES IN TRENCH
Wording The applicant may place utilities in along the back edge of the right-of-way of Elkins Rd. from mile post .01 left to mile post .04 left.

Title: P-WATER SERVICE LINE
Wording The applicant may install a water service meter on the back edge of the right of way on Elkins Rd. at mile post .04 left.