Case Number:BLD2022-00239 Case Status:Approved Date Received:4/29/2022
Description:INSTALL NEW MANUFACTURED HOME Date Issued:7/18/2022
Applicant: REESE TRUST Expiration Date:7/18/2023 12:00:00 AM
Site Address:74 SUNSET MEADOWS LN Case Finaled:
Parcel No:971900006 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: Issue Building Permit (F)
Date Completed: 7/18/2022
Disposition: DONE
Description: A Clock Interrupt
Date Completed: 7/18/2022
Disposition: DONE
Description: Additional Info Request-DRD
Date Completed: 7/18/2022
Disposition: DONE
Description: Insp - Sheet Flow Dispersion
Date Completed:
Disposition:
Description: Insp - Drywell/Alt Drainage
Date Completed:
Disposition:
Description: Insp - Final Building
Date Completed:
Disposition:
Description: Insp - MH Foundation
Date Completed:
Disposition:
Description: Insp - Framing
Date Completed:
Disposition:
Description: Insp - Ext. Shear Wall Nailing
Date Completed:
Disposition:
Description: Insp - Straps (hold downs)
Date Completed:
Disposition:
Description: Insp - Footing Drains
Date Completed:
Disposition:
Description: Insp - Erosion Control
Date Completed:
Disposition:
Description: Insp - Setbacks
Date Completed:
Disposition:
Description: Septic System Finaled
Date Completed:
Disposition:
Description: Address Review Complete
Date Completed: 6/27/2022
Disposition: DONE
Description: RAP Review Complete-U
Date Completed: 5/3/2022
Disposition: DONE
Description: Consistency Review-U
Date Completed: 7/15/2022
Disposition: DONE
Description: Env. Sensitive Area Review-U
Date Completed: 7/15/2022
Disposition: DONE
Description: Stormwater Review-U
Date Completed: 7/18/2022
Disposition: DONE
Description: Contractor License/Bond Info
Date Completed: 4/29/2022
Disposition: DONE
Description: Plan Check
Date Completed: 5/6/2022
Disposition: DONE
Description: Potable Water Approval
Date Completed: 5/26/2022
Disposition: DONE
Description: Septic Review Complete-U
Date Completed: 5/26/2022
Disposition: DONE
Description: Case Entered
Date Completed: 4/29/2022
Disposition:
Description: App Substantially Complete-U
Date Completed:
Disposition:

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: APPROVAL
Wording This approval is for a new manufactured home only. Any future permits on this site are subject to review for consistency with applicable codes and ordinances and does not preclude review and conditions which may be placed on future permits.

Title: SITE PLAN CHANGES
Wording The revised site plan as submitted with the manufactured application on July 18, 2022 has been reviewed for consistency under the UDC, and has been approved by Jefferson County Department of Community Development. Any modifications, changes, and/or additions to the stamped, approved site plan dated July 18, 2022 shall be resubmitted for review and approval by Jefferson County Department of Community Development.

Title: CRITICAL AREAS
Wording The Geographic Information Systems mapping review identified the following Critical Areas on the subject property: SARPA

Title: BMPS
Wording The project shall adhere to the Best Management Practices (BMPs) to control stormwater, erosion and sediment during construction. BMPs shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems.

Title: MEDIUM STORMWATER
Wording The applicant is proposing to create or add 2338 square feet of impervious surface and 2338 square feet of land disturbing activities (for both manufactured home and detached garage (BLD2022-00240). JCC 18.30.060 and 18.30.070 require the project applicant submit a stormwater plan meeting Minimum Requirements #1 through #5 of the Department of Ecology Stormwater Management Manual for Western Washington. The stormwater plan shall address measures to control stormwater, erosion and sediment during construction and shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems.

Title: STORMWATER PLAN
Wording A Stormwater Plan has been submitted and approved by the Department of Community Development. Once the subject permit has been issued the applicant shall fully implement the provisions of the submitted plan. No clearing for roadways or utilities shall occur on the project site until clearing necessary for the installation of temporary sedimentation and erosion control measures have been completed.

Title: DRYWELL
Wording The applicant has proposed and been approved to utilize downspout full infiltration to manage stormwater from roof areas. The soils were evaluated by using the septic soil logs and found to have three or more feet of permeable soils and the anticipated water table is at least 1 foot below the bottom of the proposed drywells. The drywells will be designed per the requirements of the Stormwater Management Manual for Western Washington BMP T5.10. The drywell shall be 5' wide x 12' long x 4' deep.

Title: SHEET FLOW
Wording The applicant has proposed and been approved to utilize sheet flow dispersion for driveway stormwater management. The sheet flow shall be designed per the requirements of the stormwater manual. A 2-foot wide gravel transition zone and 10-feet of vegetated flow path are required.

Title: BINDING SITE PLAN
Wording This application and property is subject to all requirements from the binding site plan for "landominiums" recorded under AFN 629481.

Title: Water line/Septic system setback
Wording 10' minimum separation required between the water line and any onsite sewage system components including sewage transport lines.

Title: SEPTIC - No Assurance future dev.
Wording Approval of this permit does not provide any assurance of future approvals for onsite sewage disposal on the property or use of any existing septic systems. Actions taken to date and proposed as part of this project may limit or prevent future development of an onsite sewage system. Future proposals must meet current code at the time of application.

Title: Septic - Stormwater setbacks
Wording SEPTIC SYSTEM COMPONENT SETBACKS TO STORMWATER MANAGEMENT FACILITIES - Any interceptor/curtain drain or foundation drain, or any other source of water that is downgradient or below MUST be setback a minimum of 30’ from any septic system dispersal area (drainfield) and 5’ from any septic tanks. Splash blocks must be directed away from ALL septic components.