Permit Case Summary

Case Number: Search Help

Case Number:BLD2008-00459 Case Status:Finaled Date Received:10/22/2008
Description:NEW GARAGE ATTACHED TO M/H - UNHTD, NO PLMB Date Issued:2/10/2009
Applicant: OLYMPIC GREENS RESIDENTS ASSOC. Expiration Date:2/10/2010 12:00:00 AM
Site Address:92 OLYMPIC GREENS DR Case Finaled:9/30/2009
Parcel No:971900008 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: File Archived
Date Completed: 6/30/2010
Disposition: DONE
Description: Insp - FINAL FINAL Building
Date Completed: 9/30/2009
Disposition: DONE
Description: Insp - Final Building
Date Completed: 9/30/2009
Disposition: DONE
Description: Insp - Final Building
Date Completed: 9/8/2009
Disposition: FAIL
Description: Issue Building Permit (F)
Date Completed: 2/10/2009
Disposition: DONE
Description: Approve Permit-UF
Date Completed: 2/9/2009
Disposition: DONE
Description: Review Complete-U
Date Completed: 2/9/2009
Disposition: DONE
Description: Insp - Setbacks
Date Completed: 9/30/2009
Disposition: DONE
Description: Insp - Erosion Control
Date Completed: 9/30/2009
Disposition: DONE
Description: Insp - Ext. Shear Wall Nailing
Date Completed: 9/30/2009
Disposition: DONE
Description: Insp - Framing
Date Completed: 7/28/2009
Disposition: DONE
Description: Insp - Drywell/Alt Drainage
Date Completed: 9/30/2009
Disposition: DONE
Description: Insp - Address Posted
Date Completed: 9/30/2009
Disposition: DONE
Description: Septic System Finaled
Date Completed:
Disposition:
Description: Additional Info Request-U
Date Completed: 2/9/2009
Disposition: DONE
Description: Det. of Completeness-UF
Date Completed: 10/30/2008
Disposition:
Description: Building Permit Application(F)
Date Completed: 10/28/2008
Disposition: DONE
Description: App Substantially Complete-U
Date Completed: 10/30/2008
Disposition: DONE
Description: Case Entered
Date Completed: 10/23/2008
Disposition:
Description: Plan Check
Date Completed: 11/4/2008
Disposition: DONE
Description: Septic Review Complete-U
Date Completed: 2/6/2009
Disposition: DONE
Description: Potable Water Approval
Date Completed: 10/23/2008
Disposition: DONE
Description: Contractor License/Bond Info
Date Completed: 10/28/2008
Disposition: DONE
Description: Stormwater Review-U
Date Completed: 11/12/2008
Disposition: DONE
Description: Env. Sensitive Area Review-U
Date Completed: 11/12/2008
Disposition: DONE
Description: Consistency Review-U
Date Completed: 2/9/2009
Disposition: DONE
Description: RAP Review Complete-U
Date Completed: 10/23/2008
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: Bld Security/hooded lights
Wording Lighting fixtures shall be designed and hooded to prevent the light source from being directly visible from outside the boundaries of the property. The intensity or brightness of all lighting, during construction and after project completion shall not adversely affect the use of surrounding properties or adjoining rights-of-way.

Title: Bld Exterior height lights
Wording Exterior lighting for residential uses shall not exceed twenty feet (20') in height from the finished grade, excepting when such lighting is an integral part of a building or structure. Ground level lighting is encouraged.

Title: Bld building height
Wording The building height is not to exceed 35 feet.

Title: Outdoor Residential Storage
Wording Outdoor residential storage shall be maintained in an orderly manner and shall create no fire, safety, health or sanitary hazard.

Title: Unlicensed/Inoperable Vehicles
Wording Not more than 2 unlicensed vehicles shall be stored on any lot unless totally screened from view of neighboring dwellings and rights-of-way. Such screening shall meet all applicable performance and development standards specific to the district in which the storage is kept, and shall be in keeping with the character of the area. Screening shall meet the requirements of Chapter 18.30 JCC. Outdoor storage of 3 or more junk motor vehicles is prohibited except in those districts where specified as an automobile wrecking yard or junk (or salvage) yard and allowed as a permitted use in Table 3-1 or Chapter 18.18 JCC, and such storage shall meet the requirements of JCC 18.20.100, Automobile wrecking yards and junk (or salvage) yards. In no case, shall any such junk motor vehicles be stored in a critical area.

Title: SFR PARKING
Wording A minimum of two (2) on-site parking spaces shall be provided for the single family residence.

Title: SETBACKS
Wording Setback from Olympic Greens Dr. right-of-way is no less than 20 ft., side and rear setbacks are no less than 5 ft. from parcel boundaries If an environmentally sensitive area (ESA) is present, then the more restrictive setback shall apply.

Title: STORMWATER ON SITE
Wording Stormwater shall be retained and infiltrated on site. The owner shall control all sedimentation and erosion on the property.

Title: SILT FENCE
Wording SILT FENCE A SILT FENCE SHALL BE INSTALLED AT PARCEL BOUNDARIES AND WETLAND BUFFER TO CONTAIN EROSION AND PREVENT SEDIMENT RUNOFF TO ADJACENT PROPERTIES AND WETLAND BUFFER. THE MINIMUM HEIGHT OF THE TOP OF SILT FENCE SHALL BE 2 FEET AND THE MAXIMUM HEIGHT SHALL BE 2 1/2 FEET ABOVE THE ORIGINAL GROUND SURFACE. THE SILT FENCE SHALL BE BURIED IN A TRENCH TO A MINIMUM DEPTH OF 5 INCHES BELOW THE GROUND SURFACE. THE TRENCH SHALL BE BACKFILLED AND THE SOIL TAMPED IN PLACE OVER THE BURIED PORTION OF THE SILT FENCE, SUCH THAT NO FLOW CAN PASS BENEATH THE FENCE AND SCOURING CAN NOT OCCUR. ANY DAMAGE TO THE SILT FENCE SHALL BE REPAIRED IMMEDIATELY. SEDIMENT DEPOSITS SHALL EITHER BE REMOVED WHEN THE DEPOSIT REACHES APPROXIMATELY ONE-THIRD THE HEIGHT OF THE SILT FENCE, OR A SECOND SILT FENCE SHALL BE INSTALLED.

Title: DRYWELL
Wording DRYWELL BOTTOMS MUST BE A MINIMUM OF 1 FOOT ABOVE SEASONAL HIGH GROUNDWATER LEVEL OR IMPERMEABLE SOIL LAYERS. EACH DRYWELL MAY SERVE UP TO 1,000 SQUARE FEET OF IMPERVIOUS SURFACE FOR EITHER MEDIUM SANDS OR COARSE SANDS. DRYWELLS ARE 48 INCHES IN DIAMETER (MINIMUM) AND HAVE A DEPTH OF 5 FEET (4 FEET OF GRAVEL AND 1 FOOT OF SUITABLE COVER MATERIAL). FILTER FABRIC (GEOTEXTILE) MUST BE PLACED ON TOP OF THE DRAIN ROCK AND ON TRENCH OR DRYWELL SIDES PRIOR TO BACKFILLING. SPACING BETWEEN DRYWELLS MUST BE A MINIMUM OF 4 FEET.

Title: BMP'S SPECIFIED
Wording The project shall adhere to the Best Management Practices (BMPs) to control stormwater, erosion and sediment during construction. SEE ATTACHED INFORMATION SHEETS FOR DESIGN STANDARDS FOR ALL BMP's LISTED. BMP C103, MARK CLEARING LIMITS MARK CLEARING LIMITS. 2005 DOE Manual BMP C103 High Visibility Plastic or Metal Fencing BMP C105, ESTABLISH CONST. ACCESS ESTABLISH CONSTRUCTION ACCESS 2005 DOE Manual BMP C105 Stabilized Construction Entrance BMP C233, SILT FENCE INSTALL SEDIMENT CONTROLS - SILT FENCE 2005 DOE Manual BMP C233 Silt Fence BMP C120,121 - STABILIZE SOIL STABILIZE SOILS 2005 DOE Manual BMPs C120 , C121 BMP C151 - CONTROL POLLUTANTS 2005 DOE Manual BMP C151 - Concrete Handling MANAGE THE PROJECT Maintain BMP's as prescribed in individual MAINTENANCE STANDARDS per BMP's above.

Title: Do Not Disturb Buffer
Wording All construction activities shall not encroach upon the wetland buffer. This includes the storage or preparation of materials.

Title: Wetland Setback
Wording A setback of 50-feet, measured perpendicularly from the wetland edge, shall be permanently maintained as a buffer. The buffer ends at the eastern property line. No filling, grading, clearing, or other alteration of the wetland or its buffer is allowed.

Title: Identify Wetland Buffer
Wording A permanent physical separation along the upland boundary of the wetland buffer area shall be installed and permanently maintained. Such separation can include installing logs, trees, a hedgerow, or any other prominent physical marking approved by the UDC Administrator.

Title: Mark Wetland Buffer Drng Cnstrctn
Wording Buffer perimeters shall be marked with temporary signs at an interval of one per parcel or every one hundred (100) feet, whichever is less. Signs shall contain the following statement: "Wetland & Buffer - Do Not Remove or Alter Existing Vegetation."

Title: BMPs
Wording The project shall adhere to the Best Management Practices (BMPs) to control stormwater, erosion and sediment during construction. BMPs shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems.

Title: Stormwater Plan
Wording A Stormwater Management Plan has been submitted and approved by the Department of Community Development. Once the subject permit has been issued the applicant shall fully implement the provisions of the submitted plan and contact the Jefferson County Department of Community Development to arrange a schedule to inspect the property for plan compliance. A Certificate of Occupancy will not be issued until the Department verifies plan compliance. No clearing for roadways or utilities shall occur on the project site until clearing necessary for the installation of temporary sedimentation and erosion control measures have been completed.


Case Findings
Below is a list of findings for this permit case. Findings typically record facts that the staff are using as the basis of their permit processing decisions.
Title: F-ZONING
Wording This is a legal conforming parcel, approximately 16.81 acres in size according to Jefferson County Assessor's Records, and is designated as Rural Residential 1:10 and Rural Residential 1:5 under the Jefferson County Comprehensive Plan Land Use Map effective August 28, 1998, as amended. Lot 8 of the Olympic Greens Binding Site Plan is approximately .175 acres in size and is zoned Rural Residential 1:10.

Title: F-WATER
Wording This parcel is served by a Public Utility District - Quimper water system.

Title: F-SEPTIC
Wording A septic permit (SEP08-00224) tank only permit for connecting to existing community system was applied for on 10/30/2008 for a capacity of 240 gallons per day.

Title: F-ACCESS
Wording Olympic Greens Drive (P506) is a private road. A road approach is existing and an address of 92 Olympic Greens Dr has been assigned to the parcel.

Title: F-PARCEL CREATION
Wording This parcel was created through the Olympic Greens Retirement Community BSP on August 3, 1997 under AFN 402752 Volume 1, page 24-27 with the Jefferson County Auditor's office and is subject to plat conditions and community Covenanants Conditions & Restrictions (CC & R's).

Title: F-NO PROTEST AGREEMENT
Wording A Restrictive Covenant for Irondale/Hadlock Sanitary Sewer System No Protest Agreement was recorded 11/10/2008 under AFN 538595 with the Jefferson County Auditor.

Title: F-LOT COVERAGE
Wording Pre-existing legal lots of record less than one acre in size in rural residential districts are subject to the stormwater requirements in Chapter 18.30 JCC and must meet the "Area of Impervious Surface Coverage" to the maximum extent practicable as determined by the administrator. Lot coverage is defined as amount of impervious surface, which includes rooftops, driveways, concrete, etc.

Title: F-Confirmed ESAs
Wording The application was reviewed by the Jefferson County Department of Community Development staff on 10/30/2008 for the potential presence of Environmentally Sensitive Areas (ESAs) under the provisions of the Unified Development Code (UDC). After an initial Geographic Information Systems mapping review, the following ESAs were confirmed to be present on the subject property: Wetland adjacent, Special Aquifer Recharge Protection Area.

Title: F-Aquifer Recharge Area
Wording Aquifer Recharge Areas in Jefferson County are characterized by porous geological formations that allow percolation of the surface water into the soils and the underlying zone of saturation. Aquifers are geologic formations that contain sufficient saturated permeable material to yield significant quantities of water to wells and springs. Aquifers serve as the source of drinking water within most of the rural portions of Jefferson County.

Title: F-Critical Aquifer Recharge Area
Wording Critical Aquifer Recharge Areas are defined as Seawater Intrusion Areas, and Special Aquifer Recharge Protection Areas and the following land uses located within Susceptible Aquifer Recharge Areas (1) All Industrial Land Uses (2) All Commercial Uses (3) All Rural Residential Land Uses requiring a Discretionary Use or Conditional Use Permit (4) All Rural Residential Land Uses with nonconforming uses that would otherwise require a Discretionary Use or Conditional Use Permit (5) Unsewered Planned Rural Residential Developments (6) Unsewered residential development with gross densities greater than one unit per acre. All of the above listed uses shall be subject to the applicable requirements and standards of the Jefferson County Unified Development Code.

Title: F-Buffers
Wording Wetland Buffers are areas that shall be maintained in their natural condition, however, minor pruning or alteration of vegetation may be permitted as long as the function and character of the buffer are not diminished.

Title: F-Medium Stormwater
Wording The applicant is proposing to create or add 2680 square feet of impervious surface and 5500 square feet of land disturbing activities. JCC 18.30.060 and 18.30.070 require the project applicant submit a stormwater plan meeting Minimum Requirements #1 through #5 of the Department of Ecology Stormwater Management Manual for Western Washington. The stormwater plan shall address measures to control stormwater, erosion and sediment during construction and shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems and protection of critical areas and critical area buffers.

Title: F-SEPA Exempt
Wording Jefferson County determined that this proposal is categorically exempt from review under the State Environmental Policy Act (SEPA) pursuant to WAC 197-11-800(1)(b)(i).

Title: F-Site Plan Changes
Wording The site plan as submitted with the building permit application on 10/22/2008 has been reviewed for consistency under the UDC, and has been approved by Jefferson County Department of Community Development. Any modifications, changes, and/or additions to the stamped, approved site plan dated 2/9/2009 shall be resubmitted for review and approval by Jefferson County Department of Community Development.

Title: F-APPROVAL FOR SFR & GARAGE ONLY
Wording This approval is for a single family residence and garage only. Any future permits on this site are subject to review for consistency with applicable codes and ordinances and does not preclude review and conditions which may be placed on future permits.

Title: F-General PMT Notice
Wording NOTICE: This permit does not excuse the proponent from complying with other local, state, and federal ordinances, regulations, or statutes applicable to the proposed development, but consistent with RCW 90.58. Development pursuant to this permit shall be undertaken subject to the applicable policies and performance standards of the Jefferson County Shoreline Management Master Program and the Jefferson County Unified Development Code. If during excavation or development of the site an area of potential archaeological significance is uncovered, all activity in the immediate area shall be halted, and the Administrator shall be notified at once. The Federal Endangered Species Act rules to protect threatened Chinook and Summer-run Chum salmon became effective on January 8, 2001. Bull trout have been listed as threatened since early 2000. Under the ESA, any person may bring lawsuit against any individual or agency that "takes" listed species (defined as causing harm, harassing, or damaging habitat for the listed species). In addition, the National Marine Fisheries Service can levy penalties. All areas in Jefferson County are included as "critical habitat" for a listed species. Development of property along any marine shoreline, freshwater shoreline, or floodplains could harm habitat if protective measures are not taken. To minimize the potential to damage habitat, all property owners developing adjacent to marine shoreline, freshwater shoreline, or floodplains are advised to do the following: - All development activities should avoid unstable slopes, wetlands, and forested areas near surface waters - Remove minimal vegetation for site development, especially large trees - Allow trees that have fallen into surface waters to remain there - Infiltrate stormwater from buildings and driveways onsite through drywells rather than discharging directly into surface waters or roadside ditches Any individual, group, or agency can bring suit for a listed species "taking", even if you are in compliance with Jefferson County development codes. The risk of a lawsuit against you can be reduced by consulting with a professional fisheries habitat biologist, and following the recommendations for site development provided by the biologist. For more information, contact the National Marine Fisheries Service in Seattle, or the U.S. Fish and Wildlife Service.