Case Number:BLD2007-00214 Case Status:Finaled Date Received:5/11/2007
Description:NEW SFR W/ ATTACHED GAR Date Issued:6/29/2007
Applicant: SEVEN BRIDGES PROPERTIES LLC Expiration Date:6/29/2008 12:00:00 AM
Site Address:22 PETE'S SPUR Case Finaled:6/20/2008
Parcel No:931300018 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: File Archived
Date Completed: 1/27/2009
Disposition: DONE
Description: Insp - FINAL FINAL Building
Date Completed: 6/20/2008
Disposition: DONE
Description: Insp - Final Building
Date Completed: 6/20/2008
Disposition: DONE
Description: Inspection Reminder Sent
Date Completed: 5/7/2008
Disposition: DONE
Description: Insp - Framing
Date Completed: 3/10/2008
Disposition: DONE
Description: Issue Building Permit (F)
Date Completed: 6/29/2007
Disposition: DONE
Description: Approve Permit-UF
Date Completed: 6/28/2007
Disposition: DONE
Description: Review Complete-U
Date Completed: 6/28/2007
Disposition: DONE
Description: Additional Info Request-U
Date Completed: 6/28/2007
Disposition: DONE
Description: Det. of Completeness-UF
Date Completed: 6/12/2007
Disposition: DONE
Description: Insp - Setbacks
Date Completed: 7/2/2007
Disposition: DONE
Description: Insp - Erosion Control
Date Completed:
Disposition:
Description: Insp - Foundation Footing
Date Completed: 7/2/2007
Disposition: DONE
Description: Insp - Footing Drains
Date Completed:
Disposition:
Description: Insp - Foundation Stem Wall
Date Completed: 7/25/2007
Disposition: DONE
Description: Insp - Straps (hold downs)
Date Completed: 1/30/2008
Disposition: DONE
Description: Insp - Ext. Shear Wall Nailing
Date Completed: 1/30/2008
Disposition: DONE
Description: Insp - Rough-in Plumbing
Date Completed: 3/6/2008
Disposition: DONE
Description: Insp - Framing
Date Completed: 3/6/2008
Disposition: DONE
Description: Insp - Airseal
Date Completed: 3/10/2008
Disposition: DONE
Description: Insp - Insulation: Walls
Date Completed: 3/10/2008
Disposition: DONE
Description: Insp - Insulation: Floors
Date Completed:
Disposition:
Description: Insp - Insulation: Ceiling
Date Completed:
Disposition:
Description: Insp - Int. Shear Wall Nailing
Date Completed:
Disposition:
Description: Insp - Heat/Chimney Clearance
Date Completed:
Disposition:
Description: Insp - Drywell/Alt Drainage
Date Completed:
Disposition:
Description: Insp - Address Posted
Date Completed:
Disposition:
Description: Insp - Final Building
Date Completed: 5/29/2008
Disposition: FAIL
Description: Septic System Finaled
Date Completed: 6/19/2008
Disposition: DONE
Description: Insp - Under Floor Framing
Date Completed: 12/18/2007
Disposition: DONE
Description: Insp - Wallboard Nailing
Date Completed: 3/18/2008
Disposition: DONE
Description: Building Permit Application(F)
Date Completed: 5/14/2007
Disposition: DONE
Description: Building Permit Application(F)
Date Completed: 5/11/2007
Disposition: DONE
Description: App Substantially Complete-U
Date Completed: 6/12/2007
Disposition: DONE
Description: Case Entered
Date Completed: 5/11/2007
Disposition:
Description: Plan Check
Date Completed: 5/23/2007
Disposition: DONE
Description: Septic Review Complete-U
Date Completed: 5/29/2007
Disposition: DONE
Description: Potable Water Approval
Date Completed: 5/24/2007
Disposition: DONE
Description: Contractor License/Bond Info
Date Completed: 5/14/2007
Disposition: DONE
Description: Stormwater Review-U
Date Completed: 6/14/2007
Disposition: DONE
Description: Env. Sensitive Area Review-U
Date Completed: 6/14/2007
Disposition: DONE
Description: Consistency Review-U
Date Completed: 6/28/2007
Disposition: DONE
Description: RAP Review Complete-U
Date Completed: 6/28/2007
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: Bld Exterior height lights
Wording Exterior lighting for residential uses shall not exceed twenty feet (20') in height from the finished grade, excepting when such lighting is an integral part of a building or structure. Ground level lighting is encouraged.

Title: Bld Setbacks
Wording Setback from Pete's Spur right-of-way is no less than 20 ft., setback from Meg's Way right-of-way is no less than 20 ft., side and rear setbacks are no less than 5 ft. If an environmentally sensitive area (ESA) is present, then the more restrictive setback shall apply.

Title: Bld building height
Wording The building height is not to exceed 35 feet.

Title: Bld lot coverage
Wording Pre-existing legal lots of record less than one acre in size in rural residential districts are subject to the stormwater requirements in Chapter 18.30 JCC and must meet the "Area of Impervious Surface Coverage" to the maximum extent practicable as determined by the administrator. Lot coverage is defined as amount of impervious surface, which includes rooftops, driveways, concrete, etc.

Title: SEPTIC CONDITION FOR WATER LINES
Wording 10' SEPARATION REQUIRED BETWEEN A WATER LINE AND ALL PORTIONS OF THE ONSITE SEWAGE SYSTEM; EFFLUENT TRANSPORT LINE, TANKS, TREATMENT AND DISPOSAL COMPONENTS.

Title: SEPTIC CONDITION
Wording A MINIMUM OF 10' MUST BE MAINTAINED BETWEEN BUILDING FOUNDATION AND EDGE OF DISPOSAL COMPONENT.

Title: HOLD-SEPTIC CONDITION
Wording PRIOR TO OCCUPANCY FINAL APPROVAL OF SEPTIC SEP05-267 IS REQUIRED.

Title: Outdoor Residential Storage
Wording Outdoor residential storage shall be maintained in an orderly manner and shall create no fire, safety, health or sanitary hazard.

Title: Unlicensed/Inoperable Vehicles
Wording Not more than 2 unlicensed vehicles shall be stored on any lot unless totally screened from view of neighboring dwellings and rights-of-way. Such screening shall meet all applicable performance and development standards specific to the district in which the storage is kept, and shall be in keeping with the character of the area. Screening shall meet the requirements of Chapter 18.30 JCC. Outdoor storage of 3 or more junk motor vehicles is prohibited except in those districts where specified as an autormobile wrecking yard or junk (or salvage) yard and allowed as a permitted use in Table 3-1 or Chapter 18.18 JCC, and such storage shall meet the requriements of JCC 18.20.100, Automobile wrecking yards and junk (or salvage) yards. In no case, shall any such junk motor vehicles be stored in a critical area.

Title: STORMWATER ON SITE
Wording Stormwater shall be retained and infiltrated on site. The owner shall control all sedimentation and erosion on the property.

Title: RAP FINAL
Wording The road approach permit (RAP07-00111) must be inspected and finalled by the Jefferson County Department of Public Works prior to the final inspection/certificate of occupancy of this residence. Contact the Department of Public Works at 360-385-9160 for the final road approach inspection.

Title: PARKING
Wording A minimum of two (2) on-site parking spaces is required for the single-family residence.

Title: Aquifer Recharge Conditions (SFR)
Wording Critical Aquifer Recharge Areas may require special protection measures to mitigate water quality degradation. The submitted proposal does not require additional aquifer protection measures. However, during construction the project shall follow the Best Management Practices (BMPs) and facility design standards as identified and defined in the Stormwater Management Manual for the Puget Sound Basin.

Title: BMPs
Wording The project shall adhere to the Best Management Practices (BMPs) to control stormwater, erosion and sediment during construction. BMPs shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems.

Title: Stormwater Plan
Wording A Medium Stormwater Plan has been submitted and approved by the Department of Community Development. Once the subject permit has been issued the applicant shall fully implement the provisions of the submitted plan and contact the Jefferson County Department of Community Development to arrange a schedule to inspect the property for plan compliance. A Certificate of Occupancy will not be issued until the Department verifies plan compliance. No clearing for roadways or utilities shall occur on the project site until clearing necessary for the installation of temporary sedimentation and erosion control measures have been completed.


Case Findings
Below is a list of findings for this permit case. Findings typically record facts that the staff are using as the basis of their permit processing decisions.
Title: F-COMP PLAN
Wording This is a legal nonconforming parcel designated as Rural Residential 1:5 under the Jefferson County Comprehensive Plan Land Use Map effective August 28, 1998.

Title: F-PUBLIC WATER
Wording This parcel is served by a public water system.

Title: F-SEPTIC
Wording A septic permit (SEP05-00267) was approved September 12, 2005 for a capacity of 360 gallons per day.

Title: F-ACCESS
Wording Pete's Spur (C634209) is a county local access road. A road approach (RAP07-00111) was approved on June 28, 2007 and an address of 22 Pete's Spur has been assigned to the parcel.

Title: F-PARCEL CREATION
Wording This parcel was created through Anderson Court Long Plat under AFN 457771, recorded July 11, 2002, Volume 7, pages 165-166 with the Jefferson County Auditor's office.

Title: F-Confirmed ESAs
Wording The application was reviewed by the Jefferson County Department of Community Development staff on June 13, 2007 for the potential presence of Environmentally Sensitive Areas (ESAs) under the provisions of the Unified Development Code (UDC). After an initial Geographic Information Systems mapping review, the following ESAs were confirmed to be present on the subject property: Special Aquifer Recharge Protection Area (SARPA) and Susceptible Aquifer Recharge Area (SUSC).

Title: F-Aquifer Recharge Area
Wording Aquifer Recharge Areas in Jefferson County are characterized by porous geological formations that allow percolation of the surface water into the soils and the underlying zone of saturation. Aquifers are geologic formations that contain sufficient saturated permeable material to yield significant quantities of water to wells and springs. Aquifers serve as the source of drinking water within most of the rural portions of Jefferson County.

Title: F-Susc. Aquifer Recharge Area
Wording Susceptible Aquifer Recharge Areas are those with geologic and hydrologic conditions that promote rapid infiltration of recharge waters to groundwater aquifers.

Title: F-Critical Aquifer Recharge Area
Wording Critical Aquifer Recharge Areas are defined as Seawater Intrusion Areas, and Special Aquifer Recharge Protection Areas and the following land uses located within Susceptible Aquifer Recharge Areas (1) All Industrial Land Uses (2) All Commercial Uses (3) All Rural Residential Land Uses requiring a Discretionary Use or Conditional Use Permit (4) All Rural Residential Land Uses with nonconforming uses that would otherwise require a Discretionary Use or Conditional Use Permit (5) Unsewered Planned Rural Residential Developments (6) Unsewered residential development with gross densities greater than one unit per acre. All of the above listed uses shall be subject to the applicable requirements and standards of the Jefferson County Unified Development Code.

Title: F-Medium Stormwater
Wording The applicant is proposing to create or add 2,631 square feet of impervious surface and 13,966 square feet of land disturbing activities. JCC 18.30.060 and 18.30.070 require the project applicant submit a stormwater plan meeting Minimum Requirements #1 through #5 of the Department of Ecology Stormwater Management Manual for Western Washington. The stormwater plan shall address measures to control stormwater, erosion and sediment during construction and shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems.

Title: F-SEPA Exempt
Wording Jefferson County determined that this proposal is categorically exempt from review under the State Environmental Policy Act (SEPA) pursuant to WAC 197-11-800(1)(b)(i).

Title: F-Site Plan Changes
Wording The site plan as submitted with the building permit application on May 11, 2007 has been reviewed for consistency under the UDC, and has been approved by Jefferson County Department of Community Development. Any modifications, changes, and/or additions to the stamped, approved site plan dated June 14, 2007 shall be resubmitted for review and approval by Jefferson County Department of Community Development.

Title: F-APPROVAL FOR SFR ONLY
Wording This approval is for a new single-family residence with attached garage only. Any future permits on this site are subject to review for consistency with applicable codes and ordinances and does not preclude review and conditions which may be placed on future permits.