Permit Case Summary

Case Number: Search Help

Case Number:BLD2006-00691 Case Status:Finaled Date Received:12/7/2006
Description:NSFR W/ ATT GARAGE & A/G 500 GAL PROP TANK Date Issued:1/19/2007
Applicant:CHARLES SEIL Expiration Date:1/19/2008 12:00:00 AM
Site Address:42 BROOKSIDE ST Case Finaled:7/5/2007
Parcel No:936500001 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: File Archived
Date Completed: 12/3/2007
Disposition: DONE
Description: Insp - FINAL FINAL Building
Date Completed: 7/5/2007
Disposition: DONE
Description: Insp - Final Building
Date Completed: 7/5/2007
Disposition: DONE
Description: Insp - Int. Shear Wall Nailing
Date Completed: 6/7/2007
Disposition: DONE
Description: Insp - Airseal
Date Completed: 5/15/2007
Disposition: DONE
Description: Insp - Framing
Date Completed: 5/15/2007
Disposition: DONE
Description: Insp - Under Floor Framing
Date Completed:
Disposition:
Description: Issue Building Permit (F)
Date Completed: 1/18/2007
Disposition: DONE
Description: Approve Permit-UF
Date Completed: 1/17/2007
Disposition: DONE
Description: Print Dummy UDC Permit-UF
Date Completed: 1/17/2007
Disposition: DONE
Description: Review Complete-U
Date Completed: 1/17/2007
Disposition: DONE
Description: Det. of Completeness-UF
Date Completed: 12/22/2006
Disposition: DONE
Description: Add SF Dwelling Inspection Set
Date Completed: 12/15/2006
Disposition: DONE
Description: Insp - Setbacks
Date Completed: 4/2/2007
Disposition: DONE
Description: Insp - Erosion Control
Date Completed:
Disposition:
Description: Insp - Footing
Date Completed:
Disposition:
Description: Insp - Foundation Footing
Date Completed: 4/2/2007
Disposition: DONE
Description: Insp - Foundation Stem Wall
Date Completed: 4/2/2007
Disposition: DONE
Description: Insp - Straps
Date Completed:
Disposition:
Description: Insp - Shear Wall Nailing
Date Completed: 4/11/2007
Disposition: DONE
Description: Insp - Rough-in Plumbing
Date Completed: 5/11/2007
Disposition: DONE
Description: Insp - Underground Plumbing
Date Completed:
Disposition:
Description: Insp - Gas Line: Interior
Date Completed:
Disposition:
Description: Insp - Gas Line: Exterior
Date Completed:
Disposition:
Description: Insp - Propane Tank
Date Completed:
Disposition:
Description: Insp - Heat/Chimney Clearance
Date Completed:
Disposition:
Description: Insp - Framing
Date Completed: 5/11/2007
Disposition: FAIL
Description: Insp - Airseal
Date Completed: 5/11/2007
Disposition: FAIL
Description: Insp - Insulation: Walls
Date Completed: 5/15/2007
Disposition: DONE
Description: Insp - Insulation: Floors
Date Completed:
Disposition:
Description: Insp - Insulation: Ceiling
Date Completed:
Disposition:
Description: Insp - Int. Shear Wall Nailing
Date Completed: 6/5/2007
Disposition: FAIL
Description: Insp - Drywell/Alt Drainage
Date Completed:
Disposition:
Description: Insp - Address Posted
Date Completed:
Disposition:
Description: Insp - Final Building
Date Completed: 7/2/2007
Disposition: FAIL
Description: Septic System Finaled
Date Completed: 7/17/2007
Disposition: DONE
Description: Insp - Blocking
Date Completed:
Disposition:
Description: Insp - Wallboard Nailing
Date Completed:
Disposition:
Description: Building Permit Application(F)
Date Completed: 12/7/2006
Disposition: DONE
Description: App Substantially Complete-U
Date Completed: 12/22/2006
Disposition: DONE
Description: Case Entered
Date Completed: 12/7/2006
Disposition:
Description: Plan Check
Date Completed: 12/15/2006
Disposition: DONE
Description: Septic Review Complete-U
Date Completed: 12/14/2006
Disposition: DONE
Description: Potable Water Approval
Date Completed: 1/17/2007
Disposition: DONE
Description: Contractor License/Bond Info
Date Completed: 12/7/2006
Disposition: DONE
Description: Stormwater Review-U
Date Completed: 12/22/2006
Disposition: DONE
Description: Env. Sensitive Area Review-U
Date Completed: 12/22/2006
Disposition: DONE
Description: Consistency Review-U
Date Completed: 1/17/2007
Disposition: DONE
Description: RAP Review Complete-U
Date Completed: 12/22/2006
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: Bld Security/hooded lights
Wording Lighting fixtures shall be designed and hooded to prevent the light source from being directly visible from outside the boundaries of the property. The intensity or brightness of all lighting, during construction and after project completion shall not adversely affect the use of surrounding properties or adjoining rights-of-way.

Title: Bld Exterior height lights
Wording Exterior lighting for residential uses shall not exceed twenty feet (20') in height from the finished grade, excepting when such lighting is an integral part of a building or structure. Ground level lighting is encouraged.

Title: Bld Setbacks
Wording Minimum setback from Brookside St right-of-way shall be 20 ft. Minimum side and rear setbacks shall be 5 ft. Environmentally Sensitive Areas further impact setbacks.

Title: Bld building height
Wording The building height is not to exceed 35 feet.

Title: Bld lot coverage
Wording Maximum lot coverage is not to exceed 25%. Lot coverage is defined as amount of impervious surface which includes roof tops, driveways, concrete, etc.

Title: Outdoor Residential Storage
Wording Outdoor residential storage shall be maintained in an orderly manner and shall create no fire, safety, health or sanitary hazard.

Title: Unlicensed/Inoperable Vehicles
Wording Not more than 2 unlicensed vehicles shall be stored on any lot unless totally screened from view of neighboring dwellings and rights-of-way. Such screening shall meet all applicable performance and development standards specific to the district in which the storage is kept, and shall be in keeping with the character of the area. Screening shall meet the requirements of Chapter 18.30 JCC. Outdoor storage of 3 or more junk motor vehicles is prohibited except in those districts where specified as an autormobile wrecking yard or junk (or salvage) yard and allowed as a permitted use in Table 3-1 or Chapter 18.18 JCC, and such storage shall meet the requriements of JCC 18.20.100, Automobile wrecking yards and junk (or salvage) yards. In no case, shall any such junk motor vehicles be stored in a critical area.

Title: C-PARKING
Wording A minimum of two (2) on-site parking spaces are required for the single family residence.

Title: Streamside Setback
Wording The identified Fish and Wildlife Habitat Area (Type 2 Stream), shall maintain a vegetative buffer setback of 150 feet. The setback shall be measured horizontally from the Ordinary High Water Mark (OHWM) to the proposed single family residence.

Title: 5-Foot Stream Setback
Wording An additional setback of five (5) feet is required from the edge of the buffer area to the proposed single family residence.

Title: Identify Streamside Buffer
Wording A permanent physical separation along the boundary of the buffer area shall be installed and permanently maintained. Such separation can include installing logs, trees, a hedgerow, or any other prominent physical marking approved by the UDC Administrator.

Title: Mark Stream During Construction
Wording Buffer perimeters shall be marked with temporary signs at an interval of one per parcel or every one hundred (100) feet, whichever is less. Signs shall be in place prior to and during construction activities. The signs shall contain the following statement: "Buffer - Do Not Remove or Alter Existing Vegetation."

Title: Aquifer Recharge Conditions (SFR)
Wording Critical Aquifer Recharge Areas may require special protection measures to mitigate water quality degradation. The submitted proposal does not require additional aquifer protection measures. However, during construction the project shall follow the Best Management Practices (BMPs) and facility design standards as identified and defined in the Stormwater Management Manual for the Puget Sound Basin.

Title: BMPs
Wording The project shall adhere to the Best Management Practices (BMPs) to control stormwater, erosion and sediment during construction. BMPs shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems.

Title: Stormwater Plan
Wording A Stormwater Site Plan for a medium project has been submitted and approved by the Department of Community Development. Once the subject permit has been issued the applicant shall fully implement the provisions of the submitted plan and contact the Jefferson County Department of Community Development to arrange a schedule to inspect the property for plan compliance. A Certificate of Occupancy will not be issued until the Department verifies plan compliance. No clearing for roadways or utilities shall occur on the project site until clearing necessary for the installation of temporary sedimentation and erosion control measures have been completed.


Case Findings
Below is a list of findings for this permit case. Findings typically record facts that the staff are using as the basis of their permit processing decisions.
Title: F-ZON
Wording This parcel has been designated as Rural Residential 1:5 under the Jefferson County Comprehensive Plan Land Use Map effective August 28, 1998.

Title: F-SEP
Wording A septic permit (SEP05-00078) was approved on December 1, 2005 for a system of 480 gallons per day

Title: F-RAP
Wording Brookside St (P503) is a private access road. A road approach permit is not required and an address of 42 Brookside St has been assigned to the parcel.

Title: F-SUB
Wording This parcel was created through the Brookside Estates under AFN 394391, filed of record September 26, 1996 in Volume 6 of Long Plats, page 35-36 with Jefferson County Auditor's office.

Title: F-Confirmed ESAs
Wording The application was reviewed by the Jefferson County Department of Community Development staff on December 7, 2006 for the potential presence of Environmentally Sensitive Areas (ESAs) under the provisions of the Unified Development Code (UDC). After an initial Geographic Information Systems mapping review and an investigative site inspection, the following ESAs were confirmed to be present on the subject property: Type 2 Stream at the western edge of the lot, Seismic Hazard Area and Susceptible Aquifer Recharge Areas.

Title: F-Aquifer Recharge Area
Wording Aquifer Recharge Areas in Jefferson County are characterized by porous geological formations that allow percolation of the surface water into the soils and the underlying zone of saturation. Aquifers are geologic formations that contain sufficient saturated permeable material to yield significant quantities of water to wells and springs. Aquifers serve as the source of drinking water within most of the rural portions of Jefferson County.

Title: F-Susc. Aquifer Recharge Area
Wording Susceptible Aquifer Recharge Areas are those with geologic and hydrologic conditions that promote rapid infiltration of recharge waters to groundwater aquifers.

Title: F-Geohazard Area
Wording Geologically Hazardous Areas in Jefferson County are characterized by slope, soil type, geologic material, and groundwater that may combine to create problems with slope stability, erosion, and water quality during and after construction or during natural events such as earthquakes or severe rainstorms.

Title: F-Streams
Wording A Type 2 Stream (Fish and Wildlife Habitat Area) has been identified on the subject property. The stream will require a setback of 150-feet. The setback shall be measured horizontally from the Ordinary High Water Mark (OHWM). Fish and Wildlife Habitat Areas shall also have Buffers and Building Setbacks established.

Title: F-Buffers
Wording Buffers are areas that shall be maintained in their natural condition, however, minor pruning or alteration of vegetation may be permitted as long as the function and character of the buffer are not diminished.

Title: F-Native Vegetation List
Wording Among the native conifer species which may be used in buffers or for re-vegetation include, but are not limited to: Grand Fir (Aibes grandis), Sitka Spruce (Picea Sitchensis), Shore Pine (Pinus Contorta), Douglas Fir (Pseudotsuga Menziesii), Western Red Cedar (Thuja Plicata), and Western Hemlock (Tsuga Heterophylla). Among native tree species which may be used includes: Vine Maple (Acer Circinatum), Big-Leaf Maple (Acer Macrophyllum), Red Alder (Alnus Rubra), Pacific Madrone (Arbutus Menziesii), Quaking Aspen (Populus Tremula), Black Cottonwood (Populus Trichocarpa), Bitter Cherry (Prunus Emarginata), Oregon White Oak (Quercus Garryana), Cascara (Rhamnus Purshiana), Pacific Willow (Saliz Lasiandra), and Scouler's Willow (Saliz Scouleriana). Among the native shrub species which may be used are: Sevice-Berry (Amalanchier Alnifolia), Red Osier Dogwood (Cornus Stolonifera) Salal (Gaultheria Shallon), Ocean Spray (Holodiscus Discolor), Indian Plum (Oemlaria Cerasiformis), Pacific Ninebark (Physocarpus Capitus), Red Flowering Currant (Ribes Sanguineum), Wild Rose (Rosa Nutkana), Swamp Rose (Rosa Pisocarpa), Willows (Salix ssp.), Red Elderberry (Sambucus Racemosa), Snowberry (Symphoricarpos Albus), Evergreen Huckleberry (Vaccinium Ovatum), Red Huckleberry (Vaccinium Parvifolium).

Title: F-Medium Stormwater
Wording The applicant is proposing to create or add 2540 square feet of impervious surface and 1800 square feet of land disturbing activities. JCC 18.30.060 and 18.30.070 require the project applicant submit a stormwater plan meeting Minimum Requirements #1 through #5 of the Department of Ecology Stormwater Management Manual for Western Washington. The stormwater plan shall address measures to control stormwater, erosion and sediment during construction and shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems.

Title: F-SEPA Exempt
Wording Jefferson County determined that this proposal is categorically exempt from review under the State Environmental Policy Act (SEPA) pursuant to WAC 197-11-800(1)(b)(i).

Title: F-Site Plan Changes
Wording The site plan as submitted with the building permit application on December 7, 2006 has been reviewed for consistency under the UDC, and has been approved by Jefferson County Department of Community Development. Any modifications, changes, and/or additions to the stamped, approved site plan dated December 22, 2006 shall be resubmitted for review and approval by Jefferson County Department of Community Development.

Title: F-APPROVAL FOR SFR ONLY
Wording This approval is for a single family residence with attached garage only. Any future permits on this site are subject to review for consistency with applicable codes and ordinances and does not preclude review and conditions which may be placed on future permits.