Case Number:BLD2004-00793 Case Status:Finaled Date Received:12/1/2004
Description:NEW HOOD AND AUTOMATIC FIRE EXTINQUISHING SYSTEM - NO MLA REQUIRED Date Issued:1/11/2005
Applicant: ARCEO-BAUTISTA INC Expiration Date:1/11/2006 12:00:00 AM
Site Address:10893 RHODY DR Case Finaled:5/20/2005
Parcel No:942902802 Other Cases Parcel Data Map It More Details

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: Final Building Inspection
Date Completed: 5/20/2005
Disposition: DONE
Description: Miscellaneous inspection
Date Completed:
Disposition:
Description: Miscellaneous inspection
Date Completed:
Disposition:
Description: Miscellaneous inspection
Date Completed: 2/17/2005
Disposition: DONE
Description: Final Building Inspection
Date Completed: 2/8/2005
Disposition: DONE
Description: Miscellaneous inspection
Date Completed:
Disposition:
Description: Issue Building Permit (F)
Date Completed: 1/11/2005
Disposition: DONE
Description: Building Permit Application(F)
Date Completed: 12/15/2004
Disposition: DONE
Description: App Substantially Complete-U
Date Completed: 12/15/2004
Disposition: DONE
Description: Case Entered
Date Completed: 12/15/2004
Disposition:
Description: Plan Check
Date Completed: 1/10/2005
Disposition: DONE
Description: Contractor License/Bond Info
Date Completed: 12/15/2004
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: Bld Custom Condition
Wording 1. All exiting requirements noted on plans for signage, lighting, aisles and hardware to be installed and maintained. Permanently remove all tables that block exit aisles. 2.Grand dining room: Reverse emergency exit door to swing out and provide 44" wide exterior landing. Enlarge arch opening into grand dining room to 44" wide. 3. Repair or replace electrical connection and propane flex connection to hot water heater. Provide a report of compliance of code for water heater from a certified installer. 4.Replace non working exhaust fans in employee restroom, men's and women's restroom located near bar and in kitchen / dishwashing area. 5. Verify LPG furnaces are installed to code for venting and make up air. Provide report of compliance from a certified installer. 6. Remove shelving in grand dining room furnace closet. 7. Cap off all exposed drain lines in employee restroom. 8. Provide inspection results from electrical inspection by L&I ( inspection requested by DSD)