Septic Permit Detail

Case Number: SEP2002-00021 Received Date: 1/28/2002
Description: information from sep86-33 in this file. plan is to abandon sep86-33 per this application. 3/28/02 sp Issued Date: 5/6/2002
Case Status: F Expiration Date: 5/6/2005
Final Date: 11/20/2002
Permit Applicant: JAMES   J   GROVES
Parcel No: 942901701

Type of Work: ALT Water Source: PUB Tank Size: 1500
Number of Bedrooms: Water Type: LOC Soil Type: 1A
Size of Site: 1.45 Drainfield Length: 33 Applic Rate: 1.0
Previous Eval? SEP
Trench Width: 8.0
Staff: S PORTO
Gallons Per Day: Trench Depth: 45
Type of System: PRESSURIZED BED
System Comments: system design for 35 employees (525 gpd, ) capacity for a proposed 1.27 acres, comprising lots 19-32, with a potential bla of the the remaining land from the total 1.45 acres + the southerly adjoining parcel of turner street to possibly expand volumes in future and maintain land area requirments for aquifer recharge.
Septic Waiver Comments: setback from septic /pump tanks to property lines.
Case Notes: